Fiber Optic Systems

Fusion-Spliced.
OTDR-Certified.
Every Span.

AIT installs and certifies enterprise fiber optic infrastructure — OS2 single-mode and OM3/OM4 multi-mode — with core-alignment fusion splicing, OTDR trace certification from both ends, and end-face inspection on every connector. Full documentation at closeout.

💡OS2 · OM3 · OM4 Fiber 🔧Fusion Splicing < 0.1 dB 📡OTDR Certified Both Ends 📄Full Trace Reports 🏗️OSP & Intrabuilding 📍Chicago Metro
See It In Action

Watch a complete fiber optic installation.

From conduit pull to OTDR certification — see how AIT fusion-splices and certifies a complete fiber backbone. Every span traced from both ends with full documentation delivered at closeout.

Click to play · Fiber optic installation walkthrough
System Architecture

From conduit to cloud-ready backbone.

A five-step process from route survey to full OTDR-certified documentation.

1
📐

Route Survey

Identify conduit paths, measure distances, assess existing infrastructure, plan for minimum bend radius and access points.

2
🔧

Cable Installation

Pull OS2 or OM3/OM4 fiber through conduit, innerduct, or exposed pathway with proper pulling tension and bend radius management.

3

Fusion Splicing

Core-alignment fusion splice at every mechanical joint. Average splice loss below 0.1 dB — verified by splicer’s built-in OTDR estimate before enclosure.

4
📡

OTDR Certification

Trace every span from both ends. Full event map, loss budget, reflectance, and pass/fail result for every span and connector.

5
📄

Documentation

Full OTDR trace reports, loss budget calculations, end-face inspection photos, splice tray assignments, and as-built routing diagrams.

Materials & Equipment

Hardware Ecosystem

AIT uses professional-grade fiber, fusion splicers, and OTDR equipment on every job.

OS2 Single-Mode Fiber

9/125µm — Long-Haul Backbone

OS2 tight-buffer and loose-tube cable for inter-building and long-haul backbone runs. Supports 10G, 40G, and 100G at any practical campus distance with negligible attenuation.

OM3/OM4 Multi-Mode Fiber

50/125µm Laser-Optimized

OM4 laser-optimized multi-mode for intrabuilding backbone. Supports 10G to 400m and 40G/100G at shorter distances. Cost-effective for within-building distribution.

Core-Alignment Fusion Splicer

Fujikura / Sumitomo Grade

Professional core-alignment fusion splicer. Every splice tested before enclosure. Average loss below 0.05 dB — well under the 0.1 dB maximum.

OTDR (Optical Time-Domain Reflectometer)

High-Resolution Trace Both Ends

Traces every span from both ends — identifying every event: splices, connectors, bends, breaks. Full event map, loss budget, and reflectance measurements.

Fiber Enclosures & Patch Panels

Rack-Mount & Wall-Mount

1U and 2U rack-mount fiber patch panels, wall-mount splice enclosures, and splice cassettes. All ports labelled, numbered, and keyed to your cable schedule.

MTP/MPO Trunk Cables

12 & 24 Fiber Pre-Terminated

Factory-terminated 12 and 24-fiber MTP/MPO trunk cables for high-density data center and distribution backbone. Tested, labeled, and ready to install.

Fiber Types

OS2, OM3, OM4 — the right glass for every run.

AIT installs all fiber types across all application scenarios.

Inter-Building OSP

Armored direct-bury or aerial OS2 cable for campus and between-building connections. Gel-filled loose-tube for outdoor moisture resistance. Any distance.

IDF-to-MDF Riser

OS2 or OM4 riser cable between IDFs and MDF. Typically 12–24 fiber count with LC/SC connectors terminated in rack-mount enclosures at each end.

Data Center Backbone

High-density OM4 MTP/MPO trunk cables for core-switch-to-server connections. Supports 40G/100G with MPO-8 or MPO-12 breakout cassettes.

Emergency Splice & Repair

On-call fiber repair for cut or damaged cables. Fusion splice restoration with OTDR verification — typically same-day response in the Chicago metro area.

OTDR Recertification

Re-certify existing fiber plant after moves, adds, or changes. OTDR traces both ends, new loss budget report, and updated cable schedule documentation.

End-Face Inspection

Every connector inspected per IEC 61300-3-35. Contaminated connectors cleaned and re-inspected. Microscope photos included.

Technical Standards

OTDR-traced. Loss-budget-verified.

Every fiber run AIT installs is tested to industry standards with documented results.

OTDR Traced Both Ends

Every span traced from both directions. Full event map with distance and dB values per event.

Loss Budget Analysis

Maximum allowable insertion loss calculated for every span. If measured loss exceeds budget, the span is reworked before closeout.

IEC 61300-3-35 End-Face Inspection

Every connector end-face inspected with fiber microscope. Any contamination cleaned and re-inspected. Photos in documentation package.

ANSI/TIA-568.3-D Compliance

All fiber installations follow ANSI/TIA-568.3-D — splice tray capacity, enclosure standards, bend radius, and pull tension all per specification.

ait-fiber-certification.json
// AIT Fiber Optic — OTDR Certification Report { “project”: “Campus Building B — IDF to MDF”, “fiber_type”: “OS2 Single-Mode”, “cable_count”: 12, “span_length_ft”: 487, “spans”: [{ “id”: “SPAN-01”, “end_a”: “MDF-FP01”, “end_b”: “IDF-2-FP01”, “otdr_tested”: true, “insertion_loss_db”: 0.38, “loss_budget_db”: 1.5, “result”: “PASS ✓” }], “avg_splice_loss_db”: 0.04, “splice_method”: “fusion”, “end_face_inspection”: true, “connector_type”: “LC/UPC”, “installed_by”: “AIT Communication Group” }   // Status: ALL SPANS CERTIFIED ✓
Deployment Options

Right-sized for every fiber project.

From a single riser run to a full campus OSP backbone — AIT installs and certifies it all.

🔦

Single Riser

1–4 Fiber Runs · Intrabuilding
OS2 or OM4 riser cable
LC/SC terminations
Rack-mount enclosures
OTDR certified both ends
As-built documentation
Get a Quote
Most Popular
🏢

Multi-Floor Backbone

2–6 IDFs · 12–24 Fiber
OS2 backbone IDF-to-MDF
Splice tray enclosures per IDF
OTDR from both ends
Loss budget report + cable schedule
Rack elevation drawings
Get a Quote
🏭

Inter-Building Campus

OSP · Armored · Long-Span
Armored direct-bury or aerial
Gel-filled loose-tube outdoor
OTDR with end-face inspection
Full OSP documentation
Get a Quote
🔄

Splice & Repair

Emergency or Scheduled
Same-day response Chicago metro
Core-alignment fusion splice
OTDR verification post-repair
Updated cable schedule
Get a Quote
Questions & Answers

Everything you need to know.

OS2 is single-mode — ideal for long distances (campus, inter-building) and any bandwidth. OM3 and OM4 are multi-mode — cost-effective for shorter runs. OM4 supports 10G to 400m. We’ll recommend the right type based on your distances and bandwidth needs.

Fusion splicing thermally joins two fiber ends with an electric arc — creating a continuous glass connection with typical loss below 0.05 dB. It’s stronger and lower-loss than mechanical splicing. For permanent backbone runs, fusion splicing is the professional standard.

An OTDR sends a light pulse into the fiber and measures reflections over distance. It identifies every event on the span: splices, connectors, bends, and breaks. We trace from both ends because some events are only visible from one direction.

Yes. We install armored direct-bury OS2 cable for underground runs and lashed aerial cable for overhead routes. We handle conduit boring, pull boxes, and vault installation when required.

Yes — same-day emergency fiber repair in the Chicago metro area. We’ll locate the break with OTDR, expose the cable, fusion splice the repair, and re-certify with a new OTDR trace.

Every fiber project includes: OTDR trace reports from both ends, loss budget calculations, end-face inspection photos, splice tray assignment map, and as-built routing diagrams. All as PDF at project closeout.

Ready to Build Your Fiber Backbone?

AIT installs and certifies fiber optic systems across Chicago Metro, IL and IN.

OS2, OM3, OM4 — fusion-spliced and OTDR-certified. Get a free site assessment and fixed-price proposal.

📍